DUNNE ISOLATIE: meer met minder

  • Increase font size
  • Default font size
  • Decrease font size

ISOBOOSTER performance


Product R (m2.K/W) U (W/m2.K) Cross-section Weight



ISOBOOSTER - T2 3,4 0,29 4,0 cm 650 gr/m2
ISOBOOSTER - T1 2,4 0,42 2,4 cm 300 gr/m2

The difference between building envelopes with reflection and without reflection becomes clear in the next graph. Isobooster is produced according the ISO-standard 6946:2007 which takes into account an airgap of  5 mm minimum between layers of aluminium.

WEERSTAND_GRAFIEK_R_EN

The measured values are compared to calculations according to the European standard EN ISO 6946. This standard gives a method for the calculation of the warmth capacitance of building components. Also the case of airgaps, limited by a reflecting surface (with low emissivity) is taken into consideration. The average difference between the calculated values regarding warmth capacitance and the measured values is 0.1 m. ² K/W.  (Source: WTCB: INITIAL THERMAL PERFORMANCES OF THIN REFLECTING PRODUCTS REPORT 9 - 2006)